I usually only see them when a duct detector is above a ceiling, but I don't see them 100% of the time. Description. This quiz is based on the 2019 NFPA 72, 2018 NFPA 90A and 2018 International Building Code (IBC). Let's look at the requirements in two of the prominent codes and standards. November 2022 This allows the user to test the detector to ensure that it is working properly. November 2017 Green indicates power as well as that the detector board is in place. Oh my! Engineering drawings typically have the location of installation to comply with code requirements. Already a Member? Additionally, some test switches require specialised training to use, which can add to the cost. It spreads smoke that can harm theoccupants of the facility where it is located. When do Duct Detectors require that a RTS? Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. Current: 4 A, max. November 2020 . August 2021 Full content visible, double tap to read brief content. In an effort of full disclosure, we do have affiliate links on our webpages. Joe Meyer, PE, is a Fire Protection Engineer out of St. Louis, Missouri who writes & develops resources for Fire Protection Professionals. The fire alarm systems primary goal is to enable occupants to escape more quickly and allow a safer building for firefighters to enter. Furthermore, consult the detector installation instructions for additional information. Fire Alarm The code details why smoke detectors are required along with the intentions of installing duct smoke detectors inside the ductwork to comply with code requirements. Description. July 2021 As with our duct smoke detectors, all duct smoke detectors accessories are UL listed. So, are duct detector test switches required? Switch ratings (SD-TRK) Voltage: 125 Vdc, max. We are sorry to hear of the passing of Steve Schilb, longtime employee of Harrington Signal and Potter Electric. Close this window and log in. Brand: Viking FireAlarm.com Part #: 84240 Manufacturer Part #: 23878AE. We are sorry. Career June 2019 Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. Always read the manufacturers instructions, guidelines, and recommendations when installing and testing smoke detectors in the ductwork. The PAD100-DRTS provides a supervised remote test switch for the PAD100-DUCTR duct detector. The Potter Electric PAD300-DUCT duct smoke detector provides early detection of smoke and products of combustion present in air moving through HVAC ducts in commercial, industrial and residential applications. The switch is used to simulate a smoke condition in the ductwork so that the detector can be tested. Active and Pilot LEDs provide status of the PAD100-DUCTR detector. I actually lost sleep. H0160-00 [7.2] Photo Detector Board 1. In the event your product doesnt work as expected, or youd like someone to walk you through set-up, Amazon offers free product support over the phone on eligible purchases for up to 90 days. SuperDuct detectors feature a unique design that speeds installation and . Passive Fire Protection Yes, if the duct detector cannot be reset at the FACP or annunciator, then a separate test/reset station will need to be installed for resetting the duct detector per NFPA 72 section 23.8.5.4.6.4 . Announcements October 2018 But opting out of some of these cookies may have an effect on your browsing experience. The test switch doesn't test the duct detector per NFPA 72 Table 14.4.2.2(g), so it is just supplemental. To test the duct detector, the user simply needs to activate the test switch. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG . May 2022 We and our partners use cookies to Store and/or access information on a device. Additionally, when they are not connected to a fire alarm system, duct detector wiring will not cause a trouble signal if/when they fail due to a wiring fault. Life Safety Duct Smoke Detection - NFPA 90A Code Requirements There are exceptions to the two basic requirements: Additionalreferences to smoke detector safety in air conditioning and heating systems installation can be found using the following resources: In addition to theinstallationrequirements for smoke dampers and fire dampers, the code requirement for any safety devices in ductwork ventilation systems is necessary for basic life and safety. If one senses smoke, the rest will switch their relays, with the triggered detector reporting to the fire alarm panel so the source can be pinpointed. This ACP remote alarm is hardwired to the duct smoke detector and has three LED lights for various notifications: green for pilot, red for alarm, and yellow for fault/trouble alerts. Special requirements for installation and successful operation make it necessary for a trouble-free installation. to 1 ft; ST-50 - Sampling Tube for Ducts 3 ft to 5 ft; WP-2000 - Weather Resistant Enclosure for Duct Housing Some links on this website may take you to other third-party sites and you acknowledge and agree that HKTDC and the HKTDC Affiliates have no responsibility for the accuracy or availability of any information provided by those linked websites. The housing goes around the detector and one of two sensing tubes. But what are they and what do they do? Test switches can be quite expensive, and they are not always necessary. without a test switch, it is very difficult to properly assess whether or not a duct detector is working correctly. Specifications. Of course, everything should be tested multiple times by different authorities to ensure the proper sequence of operation. R emove the screen by gently grasping on each side and pull- ing straight off. The question: Where do you install duct detectors in the ductwork? Amazon has encountered an error. Join your peers on the Internet's largest technical engineering professional community.It's easy to join and it's free. The detector shall operate at air velocities up to 3000 feet per minute. ${cardName} not available for the seller you chose. SD505 Duct Smoke Detector Remote Test Switch; UTK Remote Probe; Sight Glass with Condensation Drain; ABS Sampling Pipe; Smoke and Heat Detector Test Kit; CO Sensor; No Entry Film; SOLO Universal Detector Removal Tool; Steel Pipe Type R2525-St; STGD Ring Nut; Scorpion Head Unit Kit SCORP 2001; Current requirements: Included in controller specification LED circuit ratings Voltage: 3 Vdc, max. The duct smoke detectors shall be connected to a fire alarm system where a fire alarm system is required by Section 907 . Duct detectors are designed to detect fires within the HVAC system and sound the alarm to give the occupants time to evacuate the building. We dont share your credit card details with third-party sellers, and we dont sell your information to others. For additional information on Potter Fire Alarm Systems visit ourFire Training Videos Section. This device is only required when the duct detector is not resettable from the FACU. Reasons such as off-topic, duplicates, flames, illegal, vulgar, or students posting their homework. 2022-06-29 / Posted By : / uno chef in fattoria ribs / . Help others learn more about this product by uploading a video! The detector can be reset by a momentary power inter-ruption, by the magnet . Duct Detectors Smoke Detection NFPA 90A Code Requirements. Return2 NFPA 90A 6.4.2.1(2) 1 Installed "downstream of the air filters and ahead of any branch connections in air supply systems". The wiring diagram graphics here are for illustration purposes only. NICET It features a test/reset function activated by a key, which is included in this order. Duct Detectors Smoke Detection - NFPA 90A Code Requirements - This article references the current NFPA 90A Standard for the Installation of Air-Conditioning and Ventilating Systems. It provides basic instruction on the installation of smoke detectors inside the ductwork. [{"displayPrice":"$90.14","priceAmount":90.14,"currencySymbol":"$","integerValue":"90","decimalSeparator":".","fractionalValue":"14","symbolPosition":"left","hasSpace":false,"showFractionalPartIfEmpty":true,"offerListingId":"nbwcQzpsRfU%2BzsbiRzhUO5QWEX8aOIUz7pabPb4hpqhP%2BxUu5ZIz4ZyNqjyOxQWsa2jJTrmmB4SJ%2FL9yJn8M0Yh0oVwqJGek0Uz6jPEAneCMe7Tav1%2BYVV0%2FcPC5P8mFCGX1ZU50uvDcz0NLHZSC5GjH%2FOEP3W7jkBUUeEcwQJX0BANOJV%2FZxJQURYDT%2BuTV","locale":"en-US","buyingOptionType":"NEW"}]. JavaScript is disabled. In installations where the duct smoke detector's controls and indicators are hidden from view, a remote test station or an LED indicator can be connected to the detector to provide these functions. Why are Smoke Duct Detectors Required on the Supply Side as noted above? This category only includes cookies that ensures basic functionalities and security features of the website. Trouble: 16.0 mA max Alarm w/o strobe: 30 mA max Alarm with strobe: 55 mA max Connections: Strip terminal, 14 AWG to 22 AWG wire Wiring Distance: 1000 Feet From Duct Smoke Detector Sounder: 85 dBA at ten feet Temperature: 14F to 140F (-10C to 60C) Humidity: 95% relative humidity; non-condensing . June 2016 The System Sensor RTS451KEY is an automatic fire detector accessory designed to test remotely located duct and beam detectors. Learn methods and guidelines for using stereolithography (SLA) 3D printed molds in the injection molding process to lower costs and lead time. November 2018 6.0 Alarm Zones: Each manual pull station, area or duct smoke detector, heat detector, sprinkler system water flow switch, and tamper switch shall annunciate as a uniquely identified point, and shall identify the device ID, location and zone assignment of the device. We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. Thanks for viewing and enjoy!Follow me on twitter!https://twitter.com/SER_Safetyinstagram:s.e.r._safetyThanks! Some questions regarding duct detector remote test stations, reset switches, and code requirements.. . , Potter Announces the PAD300 D-TECT Addressable Sensors and Bases, Potters expanded line of D-TECT Sensors and bases have been designed from the ground up with unmatched, What People Are Saying About Working With Potter. Floor Control Valve We also believe the products we link to help our site visitors find products they need to enhance or repair their HVAC equipment. November 2021 September 2017 NFPA 90a Duct Smoke Detector Requirements. Download All. WIrInG DIaGram for rtS151 to D2-2WIre DuCt Smoke DeteCtor: rtS151 remote test Station InStallatIon anD maIntenanCe InStruCtIonS 3825 Ohio Avenue, St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 630-377-6495 www . Test switches are required in order to properly test the detector and ensure that it is functioning correctly. TEST NORM ALARM 2098-9806 Remote Test . Customer Reviews, including Product Star Ratings help customers to learn more about the product and decide whether it is the right product for them.Learn more how customers reviews work on Amazon. Terminal connections shall be of the strip and clamp method suitable for 12-18 AWG wiring. 2012 International Mechanical Code (IMC) The 2012 IMC requires duct smoke detectors to be located in the return air duct or plenum upstream of any filters, exhaust air connections, outdoor air connections, or decontamination equipment and appliances. Furthermore, the NFPA specifically states that detectors installed in the air duct system shall not be used as a substitute for open-air . They are usually red in color and have a clear cover so that they can be easily seen. installed. Also, it is recommended that the installer be familiar with these requirements, with local codes, and any special requirements of the local authority having jurisdiction. This item can be returned in its original condition for a full refund or replacement within 30 days of receipt. Registration on or use of this site constitutes acceptance of our Privacy Policy. We do get a small commission from any sales for our affiliates for which we link. It looks like WhatsApp is not installed on your phone. January 2020 Last week we explored when duct-detectors are required under the International Mechanical Code (IMC). I know that there is a difference - but are these devices typically combined into a single device? Test switches, magnets, and other forms of testing that do not introduce smoke from the area being protected (i.e., the duct), through the sampling tube and into the detector chamber are not equivalent methods of testing the device per Table 14.4.3.2, 17. To get started, click a course below or to learn more about Potter Academy, click here. The consent submitted will only be used for data processing originating from this website. By joining you are opting in to receive e-mail. LEDs on each detector illuminate to provide local alarm indication, and optional accessories offer a varietyGARAGE of an-nunciation capabilities. You also have the option to opt-out of these cookies. Learn more how customers reviews work on Amazon. I also wrote and article on hva. SuperDuct is a slim feature-rich alternative to bulky duct smoke detectors. August 2018 PE Exam Keyed switch allows remote testing of the PAD100-DUCTR duct detector. They are not required for the operation of the detector, but they may be used to verify that the detector is working properly. January 2018 September 2021 max. duct smoke detector Remote test station (rear view) 1234 12 3 4 14 13 12 11 2-wire duct . We work hard to protect your security and privacy. ${cardName} unavailable for quantities greater than ${maxQuantity}. You are allowed to use a remote test switch for testing duct smoke detectors to meet the requirements of NFPA 72. November 2019 My interpretation of NFPA 72-23.8.5.4.6.4 is that a reset switch is required when the duct detector is not resettable from the FACP. April 2017 FDBZ-RTL - Remote Test Lamp for Conventional Detectors; ST-100 - Sampling Tube for Ducts 5 ft to 10 ft; AD-TGN - Test Gas Nozzle (package of 10) TSM-1 - Duct Detector Test Switch; ST-10 - Sampling Tube for Ducts 6 in. NFPA 90 states that the smoke detector should be installed in the SUPPLY after 2000 CFM, and IMC 606.2.1 says the RETURN. rybbfirealarm.com@gmail.com June 2020 Please try again later. In addition to the testing required in Table 14.4.3.2(g) (1) and Table 14.4.3.2(h), test duct smoke detectors that use sampling tubes to ensure that they will properly sample the airstream in the duct using a method acceptable to the manufacturer or in accordance with their published instructions. May 2021 Part of this maintenance is testing the function of the systems duct detectors. 2. Required fields are marked *. Thank you for helping keep Eng-Tips Forums free from inappropriate posts.The Eng-Tips staff will check this out and take appropriate action. Refer to the detector installation instructions for additional information. FOR SM-501 SERIES DUCT SMOKE DETECTORS PRODUCT OVERVIEW . June 2018 I'm wondering when they are required by code. Page 7: Testing Detector Alarm SUPERVISORY SIGNAL H0161-01 RESET TEST POWER (-) POWER (+) NOTE: Wiring diagram shown is for DH100ACDCLP 4-wire duct smoke detector system equipped without a control panel. (Remote Test Switch) NFPA 72 (2002) 72-43 5.14.5.8 Please let me know if you think my interpretation is correct on th With key, for duct smoke detector, sold in each, System Sensor RTS151KEY remote Test and reset station with key for duct smoke detector. Wiring Diagrams for Duct Smoke Detectors | Duct Detectors Smoke Detection NFPA 90A Code, Conclusion Duct Detectors Smoke Detection NFPA 90A Code Requirements, UVC Light to Kill Viruses and Other Airborne Harmful Things that Affect Health, NFPA 90a: Standard for the Installation of Air-Conditioning and Ventilating Systems, Duct Detectors Smoke Detection NFPA 90A Code Requirements. Your email address will not be published. :DS.E.R. When it comes to fire safety, there is no such thing as being too careful. Turn the key counterclockwise to the RESET position and hold. They are not required for the operation of the detector, but they may be used to verify that the detector is working properly.